cDNA protocol - Thermo Scientific RevertAid RT

Lauren Ponisio, Jocelyn Zorn

Published: 2022-11-03 DOI: 10.17504/protocols.io.36wgq4zwxvk5/v1

Abstract

cDNA protocol - Thermo Scientific RevertAid RT

Steps

Prepare workspace

1.

Thaw RNA and reagents on ice. Label four foil lids: one to replace RNA lid, one for reaction and two for aliquots

2.

UV sterilize 3 RNase free PCR plates, 8 boxes 10uL filter tips, and DEPC treated H2O

3.

Once thawed, flash spin down RNA in plate centrifuge and spin down reagents in mini centrifuge

cDNA conversion

4.

Add 1µL RNA (.1ng -5µg) to empty PCR plate

5.

Add 1µL

Note
If not using Random Hexamer Primer protocol will be different. See product handbookRevertAid RT Reverse Transcription Kit

6.

Add 10µL DEPC treated H2O

Note
If used amount other than 1µL RNA (step 1), adjust H2O volume to bring total reaction volume to 12µL

7.

Add 4µL 5X reaction buffer

8.

Add 1µL (20 U/uL)

9.

Add 2µL

10.

Add 1µL

Note
Total reaction volume should be 20µL

11.

Mix gently with pipette and centrifuge briefly on "short"

12.

Place in thermocycler and run program "cDNA"

Note
Thermocycler cDNA program: Lid 105°C. 25°C 5 min, 42°C 60 min, 70°C for 5 min, ∞ hold 4°C.

13.

Aliquot product into microplates and seal with labeled foil lid

14.

Store at -20°C for up to 1 week or -80°C for longer term storage