MTT assay on 96 well plate

Adita Ayu Permanasari

Published: 2022-11-03 DOI: 10.17504/protocols.io.6qpvr4x5pgmk/v1

Abstract

MTT assay to measure viability cells

Steps

1.

Prepare sample in DMSO

2.

Observe cell on the plate, make a note about cells condition

3.

Experiment by make a serial dilution sample in U-Type, suspend 40 times

4.

Remove old medium from cells

5.

Put 100 μl/well sample and DMSO, incubate 48 h, 37 oC

6.

Observe condition cells after 48 h incubation

7.

Checked toxicity under microscope, take photo if there are morphology changing

8.

Prepare MTT 10%

9.

Remove medium from 96 well plate

10.

Put 150 μl/well by multichannel pipet, incubate 4 h, 37 oC

11.

Remove MTT solution from well plate

12.

Put 100 μl/well DMSO 100% for dissolve

13.

Check absorbance at 560 nm and 750 nm , shaker 0.5 min before read absorbance